Find Antenna
Find Military Product Choose Frequency
From To
Choose Antenna Type
MT-364054/ND
2.3-2.7GHz 17dBi 65deg DUAL SLANT POLARITY SECTOR ANTENNA
ELECTRICAL
REGULATORY COMPLIANCE ETSI EN 302 326- V1.1.2 (2006-03), RoHS, CE 0682
FREQUENCY RANGE 2.3-2.7 GHz
GAIN 16.0 ± 0.5 dBi @ 2.3 -2.4 GHz
16.5 ± 0.5 dBi @ 2.4-2.5 GHz
17.0 ± 1 dBi @ 2.5-2.7 GHz
VSWR 1.5 : 1 (typ), 1.7:1 (max)
POLARIZATION Dual Linear, ±45º
-3dB ELEVATION BEAMWIDTH 7º (typ)
-3 dB AZIMUTH BEAMWIDTH 65° (typ)
AZIMUTH SIDELOBE LEVEL Meets ETSI EN 302 326 V.1.1.2 (2006-03)
ELEVATION SIDELOBE LEVEL Meets ETSI EN 302 326 V.1.1.2 (2006-03)
SIDE LOBES LEVEL FOR AZIMUTH IN THE RANGE
(± 100 TO ± 180 FROM BORESIGHT)
-20 dB (max) @ 2.3-2.5 GHz
-25 dB (max) @ 2.5-2.7 GHz
FRONT TO BACK -30 dB (max)
CROSS POLARIZATION -20 dB (typ) , -15 dB (max)
PORT TO PORT ISOLATION 23 dB (min), 30 dB (typ)
POWER 20W (CW), 250 W (peak)
INPUT IMPEDANCE 50 (ohm)
LIGHTNING PROTECTION DC Grounded
MECHANICAL
DIMENSIONS (LxWxD) 945 x 126 x 37mm (max)
CONNECTOR 2 xN-Type Female
MECHANICAL DOWN TILT 0º to -10º
WEIGHT 3.0 kg (max)
MOUNTING KIT MT-120021/A
RADOME MATERIAL Plastic, UV Resistant
BASE PLATE MATERIAL Aluminum with chemical conversion coating
OUTLINE DRAWING RD42532800C
ENVIRONMENTAL
TEST STANDARD DURATION TEMPERTURE NOTES
LOW TEMPERATURE IEC 68-2-1 72 h -55°C
HIGH TEMPERATURE IEC 68-2-2 72 h +71°C
TEMP. CYCLING IEC 68-2-14 1 h -45°C +70°C 3 Cycles
VIBRATION IEC 60721-3-4 30 min/axis Random4M3
SHOCK MECHANICAL IEC 60721-3-4 4M3
HUMIDITY ETSI EN300-2-4 T4.1E 144 h 95%
WATER TIGHTNESS IEC 529 IP64
SOLAR RADIATION  ASTM G53 1000h    
FLAMMABILITY  UL 94      Class HB
SALT SPRAY IEC 68-2-11 Ka 500h    
ICE AND SNOW       25mm Radial
WIND SPEED SURVIVAL OPERATION      

 220 Km/h

160 Km/h

WIND LOAD (SURVIVAL)

FRONT THRUST

SIDE THRUST

     

34 kg

10 kg

Azimuth Radiation Pattern Midband

 Freq. 2.4 GHz

Elevation Radiation Pattern Midband

Freq. 2.4 GHz

 
 
 
 
  

 

WAIVER!
While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists.

Print