Find Antenna
Find Military Product Choose Frequency
From To
Choose Antenna Type
MT-141013/V
20-100 MHz VHF HIGH POWER OMNI DIRECTIONAL ANTENNA
ELECTRICAL
FREQUENCY RANGE 20 - 100 MHz
INSTANTANEOUS BANDWIDTH 80 MHz
GAIN Unity
VSWR 5:1(max) at 20-22 MHz
3.5:1(max) at 22-100 MHz
(measured on large ground plane)
POLARIZATION Vertical
AZIMUTH PATTERN OMNI Directional
POWER HANDLING 1.5kW CW
INPUT IMPEDANCE 50 (ohm)
MECHANICAL
ANTENNA HEIGHT 1520 mm
CONNECTOR Recessed N-Type jack
WEIGHT 5kg
SPEED 240 knots (max)
MOUNTING KIT Aluminum flange with 4 x 10.5 mm holes equidistant on 114.3 mm diameter circle
WHIP BOLTING PARTS Stainless steel
BASE PLATE MATERIAL Fiberglass epoxy
WHIP MATERIAL Composite Laminate (Graphite)
ENVIRONMENTAL
TEMPERATURE OPERATING -54ºC to +71ºC
STORAGE TEMPERATURE -21ºC to +71ºC
SHOCK -54ºC to +55ºC, transition 5 minutes per MIL-STD-810F, method 503.4, proc. I
FUNCTIONAL SHOCK Saw tooth pulse 6g - 11msec, 3 axis, 3 shocks in each axis
VIBRATION 15-1000 Hz, 0.062 g²/Hz max, per MIL-STD-810F, method 514.5
HUMIDITY Per MIL-STD-810F, method 507.4, , 5 cycles, 48 hours each
RAIN Per MIL-STD-810F, method 506.4, proc. I, wind velocity 18m/sec and 33m/sec
ICING Per MIL-STD-810F, method 521.2
ALTITUDE: OPERATING 35,000 ft (max)
ALTITUDE:TEMPERTURE Per MIL-STD-810F, method 520.2, proc. III, 10 cycles
ACCELARATION Operational
Per MIL-STD-810F, method 513.5, proc. I and proc. II
Yaw – 3.6g
Down – 3g
Up – 6.5g
Aft – 6g
Fore – 2g

Structural
Yaw – 3.6g
Down – 10.5g
Up – 6.5g
Aft – 8g
Fore – 4.6g
FUNGUS Per MIL-STD-810F, method 508.5
EXPLOSIVE ATMPOSPHERE Per MIL-STD-810F, method 511.4, proc. I
Fuel “n-hexane”
Step 1 – altitude 0 ft, temperature +55ºC
Step 2 – altitude 15,000 ft, temp.+55ºC
SALT FOG Per MIL-STD-810F, method 509.4, proc. I and proc. II
SAND AND DUST Per MIL-STD-810F, method 510.4, proc. I and proc. II
SOLAR RADIATION 0 to1120 Watt/m² per MIL-STD-810F, method 505.4
CONTAMINATION BY FLUIDS Withstands the exposal to the followingoils/liquids:<BR>Motor oil 1250<BR>Hydraulic Oil

  

 

WAIVER!

While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists.

Print