Find Antenna
Find Military Product Choose Frequency
From To
Choose Antenna Type
MT-182011/NV
405 - 450 MHz, 8 dBi LINEAR POLARITY ANTENNA
ELECTRICAL
REGULATORY COMPLIANCE RoHS, CE 0682
FREQUENCY RANGE 405-450 MHz
GAIN 8 dBi (min) @ 405 – 410MHz
8 dBi (min) @ 410 – 445MHz
7 dBi (min) @ 445 – 450MHz
VSWR 2 : 1 (typ) 2.5:1 (max) @ 405 – 415MHz
1.5:1 (typ) 1.7:1 (max) @ 415 – 440MHz
2:1 (typ) 2.5:1 (max) @ 440 – 450MHz
POLARIZATION Linear Vertical
3dB ELEVATION BEAMWIDTH 68°(typ)
3dB AZIMUTH BEAMWIDTH 70°(typ)
F/B RATIO 405-410MHz @ -14dB (max)
410-450MHz @ -18dB (max)
CROSS POLARIZATION ELEVATION -18dB (max)
CROSS POLARIZATION AZIMUTH -14dB (max)@405- 410MHz
-17dB (max)@410- 425MHz
-19dB (max)@425- 440MHz at 0±90°
-15dB (max)@425-440MHz at ±90 to ±180°
-15dB (max)@440-450MHz at 0±90°
-12dB (max)@440-450MHz at ±90 to ±180°
POWER 6W (max)
INPUT IMPEDANCE 50 (ohm)
LIGHTNING PROTECTION DC Grounded
MECHANICAL
DIMENSIONS (LxWxD) 370 x 370 x 40mm (max)
CONNECTOR N-Type Female
WEIGHT 2 Kg (max)
MOUNTING KIT SEE RD41191800C
RADOME MATERIAL Plastic
BASE PLATE MATERIAL Aluminum with chemical conversion coating
OUTLINE DRAWING RD41632700C
ENVIRONMENTAL
TEST STANDARD DURATION TEMPERTURE NOTES
LOW TEMPERATURE IEC 68-2-1 72 h -55°C
HIGH TEMPERATURE IEC 68-2-2 72 h +71°C
TEMP. CYCLING IEC 68-2-14 1 h -45°C +70°C 3 Cycles
 

THERMAL SHOCK  

NONO-OPERATING
    -30°C to+70°C   Ramp 30°C/min
HUMIDITY  ETSI EN300-2-4 T4.1E 144 h   95%
WATER TIGHTNESS IEC 529 IP67
DUST RESISTANCE       IP67
SOLAR RADIATION  ASTM G53 1000h    
OZONE RESISTANCE ETSI 300      
FLAMMABILITY UL 94     Class HB
QUASI RANDOM VIBRATION 20g rms for 4 hours

VEHICLE VIBRATION

OPERATING

1 grms, 10-500 Hz, in 3 axis

    6 hours total, 2 hr in each axis. Accelerated wear – an additional 50hrs in worst case axis.

MECHANICAL SHOCK  

OPERATING
10g,11msec,  half sine pulse    

 

Azimuth Radiation Pattern Midband

 Freq. 0.425 GHz

Elevation Radiation Pattern Midband

Freq. 0.425 GHz

 
 
 
 

 

WAIVER!

While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists.