Find Antenna
Find Military Product Choose Frequency
From To
Choose Antenna Type
MT-952015 NA
2.4 – 2.5 GHz 5.0 dBi / 5.47 - 5.875 GHz, 6.5 dBi DUAL BAND POLARITY OMNI DIRECTIONAL ANTENNA
ELECTRICAL
REGULATORY COMPLIANCE RoHS, CE 0682
FREQUENCY RANGE 2.4 – 2.5 GHz
5.47 – 5.875 GHz
GAIN + GAIN RIPPLE 5.0 dBi ± 1 dB @ 2.4 – 2.5 GHz
6.5 dBi ± 1.5 dB @ 5.47 – 5.875 GHz
VSWR 2 : 1 (max)
POLARIZATION Linear Vertical
E-PLANE BEAM WIDTH 25° (typ) @ 2.4 – 2.5 GHz
13° (typ) @ 5.47 – 5.875 GHz
3dB AZIMUTH BEAMWIDTH 360°
POWER 6W (max)
INPUT IMPEDANCE 50 (ohm)
LIGHTNING PROTECTION DC Grounded
MECHANICAL
DIMENSIONS (D x H) 28 mm (max) X 260 mm (max)
CONNECTOR N-Type Male
WEIGHT 0.2 kg (max)
MOUNTING KIT Mounted to radio’s N-female output
RADOME MATERIAL Plastic, UV Resistant
BASE PLATE MATERIAL Aluminum with chemical conversion coating
OUTLINE DRAWING RD42211900C
ENVIRONMENTAL
TEST STANDARD DURATION TEMPERTURE NOTES
LOW TEMPERATURE IEC 68-2-1 72 h -55°C
HIGH TEMPERATURE IEC 68-2-2 72 h +71°C
TEMP. CYCLING IEC 68-2-14 1 h -45°C +70°C 3 Cycles
VIBRATION IEC 60721-3-4 30 min/axis Random4M5
SHOCK MECHANICAL IEC 60721-3-4 4M5
HUMIDITY ETSI EN300-2-4 T4.1E 144 h 95%
WATER TIGHTNESS IEC 529 IP67
SOLAR RADIATION  ASTM G53  1000h    
SALT SPRAY IEC 68-2-11 Ka 500h    
ICE AND SNOW       25mm Radial
WIND SPEED SURVIVAL OPERATION      

 220 Km/h

160 Km/h

 

Azimuth Radiation Pattern Midband

Freq. 2.4 GHz

 

Elevation Radiation Pattern Midband

Freq. 2.4 GHz

 
 
 

 

Azimuth Radiation Pattern Midband

 Freq. 5.47 GHz

 

Elevation Radiation Pattern Midband

Freq. 5.47 GHz

 

  

 

WAIVER!

While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists.

Print