MT-242034/NRH 865-870 MHz, 8.5 dBic RHCP READER ANTENNA |
|
|
ELECTRICAL |
REGULATORY COMPLIANCE |
RoHS, CE 0682
|
FREQUENCY RANGE |
865-870 MHz
|
GAIN |
8 dBic (min)
|
VSWR |
1.5:1 (max) 1.3:1(typ)
|
POLARIZATION |
RHCP
|
4 dBic ELEVATION BEAMWIDTH |
120° (min)
|
3dB AZIMUTH BEAMWIDTH |
33° ± 3°
|
F/B RATIO |
-20dB (max)
|
POWER |
6W (max)
|
INPUT IMPEDANCE |
50 (ohm)
|
AXIAL RATIO |
3 dB (typ) 4 dB (max) @3dB
|
LIGHTNING PROTECTION |
DC Grounded
|
MECHANICAL |
DIMENSIONS (LxWxD) |
685x626x220mm (max)
|
CONNECTOR |
N-Type Female
|
WEIGHT |
7.6 kg (max)
|
MOUNTING KIT |
See RD41181900C , MT-120019
|
RADOME MATERIAL |
Plastic
|
BASE PLATE MATERIAL |
Aluminum with chemical conversion coating
|
OUTLINE DRAWING |
RD42161800C
|
ORIENTATION |
Rectangular
|
|
|
ENVIRONMENTAL |
TEST |
STANDARD |
DURATION |
TEMPERTURE |
NOTES |
LOW TEMPERATURE |
IEC 68-2-1 |
72 h |
-55°C |
|
HIGH TEMPERATURE |
IEC 68-2-2 |
72 h |
+71°C |
|
TEMP. CYCLING |
IEC 68-2-14 |
1 h |
-45°C +70°C |
3 Cycles |
THERMAL SHOCK NONO-OPERATING |
|
|
-30°C to+70°C |
Ramp 30°C/min |
HUMIDITY |
ETSI EN300-2-4 T4.1E |
144 h |
|
95% |
WATER TIGHTNESS |
IEC 529 |
|
|
IP54 |
DUST RESISTANCE |
|
|
|
IP54 |
SOLAR RADIATION |
ASTM G53 |
1000h |
|
|
OZONE RESISTANCE |
ETSI 300 |
|
|
|
FLAMMABILITY |
UL 94 |
|
|
Class HB |
QUASI RANDOM VIBRATION |
|
|
|
2 0g rms for 4 hours |
VEHICLE VIBRATION OPERATING |
1 grms, 10-500 Hz, in 3 axis |
|
|
6 hours total, 2 hr in each axis. Accelerated wear – an additional 50hrs in worst case axis. |
MECHANICAL SHOCK OPERATING |
10g,11msec, half sine pulse |
|
|
| |
Azimuth Radiation Pattern Midband
Freq. 0.867 GHz |
Elevation Radiation Pattern Midband
Freq. 0.867 GHz |
|
| |
WAIVER!
While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists. |
Print
|
|