Find Antenna
Find Military Product Choose Frequency
From To
Choose Antenna Type

News

MT- 799002/W/RG
71-76 & 81- 86 GHz, 44.5dBi POINT to POINT 1 Ft DISH ANTENNA
ELECTRICAL
REGULATORY COMPLIANCE FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 (2010-01)
RoHS , CE 0682
FREQUENCY RANGE 71-76 & 81- 86 GHz
GAIN Low Band 43.5 dBi (min) 44.0 dBi (typ)
Middle Band 44.0 dBi (min) 44.5 dBi (typ)
High Band 44.5 dBi (min) 45.0 dBi (typ)
FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 3
VSWR 1.5 : 1 (max)
POLARIZATION Plane
3dB ELEVATION BEAMWIDTH FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 2, Class 3
1.0 deg (typ)
3dB AZIMUTH BEAMWIDTH FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 3
1.0 deg (typ)
SIDELOBE SUPPRESSION FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 3
see table 1
F/B RATIO FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 3
see table 1
CROSS POLARIZATION FCC 47CFR101.115
ETSI EN 302 217-4-2 V1.5.1 Class 3
see table 1
CROSS POLARIZATION DISCRIMINATION FCC 47CFR101.115
27 dB (min)
POWER 10 W (max)
MECHANICAL
DIAMETER Ø385 mm (max)
DEPTH 129 mm (max)
WEIGHT 3.5 kg (max)
MOUNTING KIT MT-120032/A , Weight 4kg (max)
RADOME MATERIAL Plastic
INTERFACE Circular waveguide E Band
OUTLINE DRAWING RD43877400C
TEST STANDARD DURATION TEMPERTURE NOTES
LOW TEMPERATURE IEC 60068-2-1 72 h -55°C
HIGH TEMPERATURE IEC 60068-2-2 72 h +71°C
TEMP. CYCLING IEC 60068-2-14 1 h -45°C +70°C 3 Cycles
VIBRATION IEC 60721-3-4 30 min/axis Random4M5
SHOCK MECHANICAL IEC 60721-3-4 4M5
HUMIDITY EN300 019-2-4 T4.1E 144 h 95%
WATER TIGHTNESS IEC 60529 IP67*
SOLAR RADIATION  ASTM G53  1000h    
SALT SPRAY IEC 60068-2-11 Ka 500h    
ICE AND SNOW       25mm Radial
WIND SPEED
SURVIVAL
OPERATION
ESTI EN 302 085 V1.1.2
HEAVY DUTY
HEAVY DUTY 
   

 252 Km/h

164 Km/h

    * For the feed & interface to the radio (when radio installed on antenna).

 

Table 1 

 
FCC 47CFR 101.115  1.2º - 5º    5º - 10º 10º - 15º   15º - 20º 20º - 100º   100º - 18 
Co Polar  -(Gain -28) dB  -35 dB  -40 dB  -45 dB  - 50 dB  - 55 dB
Cross Polar  -25 dB  -45 dB  -50 dB  - 50 dB  - 55 dB  - 55 dB

 

 

 

 

 

WAIVER!

While the information contained in this document has been carefully compiled to the best of our present knowledge, it is not intended as presentation or warranty of any kind on our part regarding the fitness of the products concerned for any particular use or purpose and neither shall any statement contained herein be construed as a recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of each product for any particular purpose must be checked beforehand with our specialists.

Print